home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
Libris Britannia 4
/
science library(b).zip
/
science library(b)
/
COMMUNIC
/
H191.ZIP
/
CA29-3.EXE
/
HOST.DOC
< prev
next >
Wrap
Text File
|
1992-11-30
|
16KB
|
660 lines
COM-AND Scripted HOST
-----------------------------------------
COM-AND Scripted HOST
Script based Host mode for the IBM PC
-----------------------------------------
COM-AND, and the HOST script-set (HOST, HOSETUP, et al) are
copyright 1992 by CABER Software. COM-AND is distributed freely
and may be copied by anyone for any number of machines, for
purposes of evaluation. The author offers COM-AND and its
accessory programs as a package, as "shareware". If you USE
the program after evaluating it, you MUST pay for it.
The complete user license and registration information is to be
found in the file REGISTER.DOC. Limitations on redistribution
of COM-AND are set out in the file VENDOR.DOC. These two files
are included with the COM-AND program release.
CABER Software
R. (Scott) McGinnis
P.O. Box 3607 Mdse Mart
Chicago, IL 60654-0607
GEnie, Delphi: TARTAN
CIS .......... 73147,2665
Internet ..... 73147.2665@compuserve.com
Version 1.1: 921012
COM-AND Scripted HOST
Table of Contents
-----------------
I. Introduction .............................................. page 1
A. What is COM-AND? ........................................ page 1
B. The HOST ................................................ page 1
II. Installing the HOST ........................................ page 2
A. Load HOSETUP ............................................ page 2
B. Using HOSETUP ........................................... page 2
C. Exit HOSETUP and load HOST .............................. page 3
III. External programs .......................................... page 5
A. TREED ................................................... page 5
B. DOORWAY ................................................. page 5
IV. Program Requirements ....................................... page 6
V. Program and Author Information ............................ page 7
Appendices
----------
A. Modem configuration ........................................ page 8
1. DTR ..................................................... page 8
2. CD ...................................................... page 8
3. Modem ESCAPE ............................................ page 9
4. Hangup .................................................. page 9
5. Modem Init .............................................. page 9
B. HOSTART.CMD ................................................ page 10
Version 1.1: 921012
COM-AND Scripted HOST Page 1
I. Introduction
A. What is COM-AND?
COM-AND for the IBM PC and compatibles is a communications program
for use by itself, or for use with several integrated accessory
programs (which themselves may be used independently of COM-AND).
COM-AND provides standard comm program functions: a dialing dir-
ectory, macros, disk logging, binary and ASCII file transfers, and
a script language.
B. The HOST
This document details the HOST script provided with COM-AND. Two
levels of hosting are provided. First, password protected logon
and a limited set of functions are provided. The functions are:
o C)hdir Change current directory
o F)ilelist List files in current subdirectory
o P)athlist Graphically list paths
o U)pload Upload a file using WXMODEM,
XMODEM, YMODEM, ZMODEM or KERMIT
o D)ownload Download a file using WXMODEM,
XMODEM, YMODEM, ZMODEM or KERMIT
o E)xit Logoff
Two additional functions are accessed with a second password (the
commands 'x' and 'y' are NOT listed on the HOST menu):
o X: DOS commands may be executed at this level. [NOTE: DOS
commands supporting redirected I/O are only 'usable' here.
DOS functions prompting for keyboard input may 'hang' the
HOST script.]
o Y: A drop-to-DOS is supported, using a doorway utility (such
as Marshall Dudley's DOORWAY). COM-AND is terminated, and
the doorway loaded, allowing full access to the machine.
On termination of the doorway, COM-AND is reloaded, and
the HOST script re-entered.
The supplied HOST script works best if your modem is set to report
the real state of Carrier Detect (CD). However, it has been used
quite successfully with modems reporting Carrier Detect always
true (when disconnect occurs, Hayes compatible modems report the
fact with 'NO CONNECT', and HOST is coded to look for it).
Version 1.1: 921012
COM-AND Scripted HOST Page 2
II. Installation
Included with the HOST script is a utility script, HOSETUP. HOSETUP
is used to configure the HOST if default values are not desired (and
rarely are they!).
A. Load HOSETUP
Load COM-AND and invoke HOSETUP. For example, from the DOS
prompt:
"d>" COM-AND /fHOSETUP
loads COM-AND and invokes the HOSETUP script. [This document
assumes scripts are on the current subdirectory, or the subdir-
ectory pointed by the COM-AND= environment variable.]
If HOSETUP is used to change any default values, a file, HOSTDAT
is created for the HOST script. HOSTDAT is created on the sub-
directory pointed by the COM-AND= environment variable. In the
absence of the variable, HOSTDAT is created on the current direc-
tory (in which case HOST MUST be executed from THAT directory).
B. Using HOSETUP
From HOSETUP's main menu, select the items in numeric order.
1) Identify modem values
a) Identify modem port; The default value is the default for
COM-AND. You may wish to change this for the HOST. What-
ever port you indicate becomes the HOST's comm port.
b) Identify modem speed; The default value is the default for
COM-AND. You may wish to change this for the HOST. This is
the speed set by the HOST when waiting for a call.
c) Identify modem control string; The default value for this
is appropriate for most Hayes compatible modems. It may
need modification for some modems; if so, refer to the
documentation included with the modem.
Version 1.1: 921012
COM-AND Scripted HOST Page 3
II. Installation (continued)
B. Use HOSETUP (continued)
2) Identify passwords used by HOST;
a) Identify the LOGON password. Callers may use ANY name, but
MUST use this password. The default is "****".
b) Identify the DOS password. Once connected, as described
above, DOS functions are available. To access the DOS
functions, the DOS password is required. The default is
"xxxx".
3) Identify the doorway command;
The doorway command carries both the file name of the doorway
utility, and any parameters required. For example:
c:\doorway\doorway com4 /S:* /G:ON /V:B^U /M:1000 /C:DOS /V:D
The command, exactly as typed is executed by DOS when a drop-
to-DOS is executed.
If this command is left null (its default), the drop-to-DOS
function is inhibited.
C. Exit HOSETUP and load HOST
ESC or successive carriage returns exits HOSETUP. Back in
COM-AND, invoke HOST through the F2 key. In the script prompt
window, for example, type:
\HOST\HOST
Two HOST script files are included in each release. The script
HOST.SRC is commented source for the HOST. The file HOST.CMD is a
stripped script; it contains no comments and is not very readable.
HOST.CMD is the script to be executed. Stripped, it executes
faster than HOST.SRC. HOST.SRC is provided for the intrepid who
who wish to modify the HOST.
[COM-AND does not recognize HOST.SRC as a script unless the ".SRC"
extension is stated explicitly when the script is invoked.]
Version 1.1: 921012
COM-AND Scripted HOST Page 4
II. Installation (continued)
C. Exit HOSETUP and load HOST (continued)
Having loaded HOST, it is suggested you then call in from another
PC and test the setup.
Should the use of HOST become a habit (ugh!), a simple batch file
may be used to invoke it from the DOS prompt:
COM-AND /q/fHOST
[The /q inhibits COM-AND's automatic execution of COM-AND.CMD, if
one exists. COM-AND.CMD's pausing for entry (some do, some don't)
are difficult to use in batch mode.]
Version 1.1: 921012
COM-AND Scripted HOST Page 5
III. External programs
The HOST uses two external programs to fufill its function (besides
COM-AND, of course). These are the p/d utility TREED and the share-
ware utility DOORWAY (or its equivalent).
A) TREED
The p/d utility TREED lists the tree of subdirectories on the
current drive in an easily readable graphical form. It uses the
8-bit characters in the PC ASCII character set to draw lines and
connections.
The HOST script's use of this utility is coded into the PATHLIST
command. It is easily changed to another utility.
B) DOORWAY
The shareware utility DOORWAY, by Marshall Dudley, makes a program
or the DOS prompt available from a remote site using a previously
opened communications port. Its only limitation is that it DOES
not support true graphics mode.
The HOST script's use of this utility is established through the
HOSETUP script. Whatever equivalent utility is available may be
used for the drop-to-DOS function.
NOTE: Marshall Dudley's DOORWAY is user supported. If you use
it, please register it! It may be found on most bulletin boards,
and on every major system. Registration information is provided
with every release of DOORWAY.
Version 1.1: 921012
COM-AND Scripted HOST Page 6
IV. Program requirements
This program can only function on an IBM PC or DOS compatible
machine. COM-AND does direct to screen buffer fetches and stores
(unless BIOS screen updates are directed using the /C switch or the
Alt-O options menu).
COM-AND is TopView aware even without the /C switch or Alt-O option.
COM-AND supports MDA, CGA, EGA and Hercules. COM-AND uses a Micro-
soft Mouse if one is available...
COM-AND disk I/O is done through the 'Handle' oriented I/O routines
added to DOS 2.0. Therefore DOS 2.0 is a minimum requirement.
COM-AND (Version 2.9) requires 277K for itself. You need 384K to
take advantage of the DOS Gateway and to load accessories.
This script requires a modem. This script is most reliable if the
modem is set to report true CD.
Version 1.1: 921012
COM-AND Scripted HOST Page 7
V. Author information
COM-AND was written using Microsoft Macro-Assembler. The author
likes assembler. Assembly language is an entirely appropriate
vehicle for some of the program, and a not-inappropriate vehicle
for the rest of it. Everything, in moderation...
The author of this program is R. Scott McGinnis of Chicago, IL.
My GEnie and Delphi ID is: TARTAN. Comment and suggestions (and
criticism in moderation) are welcomed:
CABER Software
R. (Scott) McGinnis
P.O. Box 3607 Mdse Mart
Chicago, IL 60654-0607
I wish to say that my wife, Elizabeth, is the best reason I've ever
known for continuing to live. Without her beside me (propping me up
alot of the time), I wouldn't be.
This script (Version 1.1) may be distributed freely (but it isn't a
whole lot of use without COM-AND). Any improvements you return to
the author will get attention... errors you report are corrected.
COM-AND is shareware. If COM-AND is USED after a 30 day evaluation,
you MUST pay for it. [Please read REGISTER.DOC.]
Most of the hardware names and software names in this document are
trademarks or trade names of specific manufacturers.
Version 1.1: 921012
COM-AND Scripted HOST Page 8
A. Modem Configuration
COM-AND defaults do not require modem pre-configuration (although
you can do it!). However, certain features cannot be used unless
you configure your modem before you use COM-AND.
1. DTR (Data Terminal Ready)
COM-AND, by default, hangs up using the command sequences defined
through the Alt-S setup (hangup and modem escape). However, you
may alternately select 'Drop DTR to hangup' through the Alt-O
options. Dropping DTR is the only way to hangup certain modems,
and is generally much faster than the command sequences.
Most Hayes compatible modems allow configuration of the DTR sense
through a switch-block. If you wish to use DTR to hangup, be sure
your modem follows the DTR signal. Refer to the documentation
provided with your modem to ensure that modem switches are set
appropriately.
2. CD (Carrier Detect)
COM-AND (presently) uses the CD sense line for several purposes.
The 'CONNECTED' test supported in the script language, test for
carrier detect upon exit, and the file transfer protocols all
require the modem report carrier detect. True carrier detect
is the only way to determine if you are 'on-line' or 'off-line'.
Many Hayes compatible modems are sold with a carrier detect
override (in other words the modem reports carrier detect all the
time). When carrier detect is overridden, COM-AND cannot detect
when carrier is lost during a file transfer or online session.
Be sure the modem is reporting true CD (instead of it just saying
'yes'). Most Hayes compatible modems allow configuration of the
CD sense through a switch-block. Refer to the documentation
provided with your modem to ensure option switches are set
appropriately.
Version 1.1: 921012 Appendices
COM-AND Scripted HOST Page 9
A. Modem Configuration (continued)
3. Modem Escape
COM-AND issues the "Modem escape" defined through the Alt-S setup,
prior to modem initialization and hangup. Be sure this value is
set correctly in Alt-S (or see below).
4. Hangup
COM-AND hangs up using the command sequences defined through the
Alt-S setup (hangup and modem escape) and the drop DTR setting as
discussed above. Be sure these values are set correctly (or see
below).
5. Modem Init
COM-AND transmits the modem initialization sequence defined by
Alt-S setup to configure the modem. HOST re-issues this initial-
ization when HOST is exited. If HOST is used, we suggest auto-
answer be turned OFF in the Alt-S modem init string.
Version 1.1: 921012 Appendices
COM-AND Scripted HOST Page 10
B. HOSTART.CMD script
The HOSTART.CMD script, included with HOST.CMD and HOST.SRC is the
means of return from DOORWAY. HOST version 1.1 looks at its invoca-
tion before it resets the modem. If HOST is FCALLed, then HOST
issues the main menu and waits for command (up to the timeout). If
HOST is NOT FCALLed, HOST resets the modem and waits for connect.
In order to make as much of the HOST machine as possible available
through the DOORWAY, when DOORWAY is invoked, COM-AND itself is
terminated (without dropping carrier). DOORWAY is loaded, and when
DOORWAY is exited (by the caller), COM-AND is reloaded with an
invocation of HOSTART. HOSTART simply FCALLs HOST, and HOST picks up
again at the main menu.
In case you were wondering...
Version 1.1: 921012 Appendices